Mega · 18 cf · 48 Slots

Mega: Forty-Eight Slots at Temperature

The Mega is Delta V's standard HTOL platform — an 18 ft³ cavity with 48 slots, engineered around the airflow path rather than the other way around.

The Standard Platform

Built Around the Airflow

HTOL systems remain the major focus within Delta V. Air flow is horizontal at high velocity to maintain the most consistent temperature performance across every slot in the cavity.

Some systems use every other slot to increase BIB (Burn in Board) height constraints — same chamber, same flow path, same control software.

Monitoring

Every Slot On the Record

Every slot is individually monitored: per-DUT & per-BIB current, real-time waveforms, and board heartbeat feedback into the BIOS control software, so a device that drifts out of condition is on the record the moment it happens rather than at the end of a 1,000-hour run.

18 cf

Cavity

18 ft³ chamber with 48 slots.

+150 °C

Temperature

+50 °C to +135 °C standard, +150 °C extended option.

7.5 kW

Without Intercooler

Max dissipation 7.5 kW @ 125 °C without the intercooler.

22 kW

With Intercooler

Liquid-cooled headroom to 22 kW for high-dissipation devices.

Per-DUT

Current Monitoring

Per-DUT & per-BIB current, real-time waveforms and heartbeat feedback.

BIOS

Control Software

Sixth-generation in-house control software, TCP/IP networked.

Same Platform

One Hardware and Software Core, Every Chamber

Every Delta V chamber runs on the same in-house hardware and BIOS, our sixth-generation TCP/IP controlled automation software for real-time monitoring, data acquisition and reporting across thousands of devices, modules and fixtures. Source is owned and retained at Delta V and never distributed to clients.

Chamber, power, drivers, burn-in boards, BOSS & Stager board certification and BIOS software are all engineered and built in Richardson, Texas — so moving a program from one chamber size to another does not mean starting over.

01

Power

Supplies sized to the bias condition, with headroom for high-dissipation GaN DC, SiC and high-power logic.

02

Drivers

Stimulus, pattern and RF drive delivery to every slot in the cavity.

03

Burn-in Boards

Custom BIBs designed per spec, with real-time heartbeat monitoring.

04

BOSS & Stager

Proprietary board certification and staging: every board proven good before it holds a program hostage.

05

BIOS Software

Sixth-generation in-house control software with GUI test programming, serial-number tracking and enterprise database reporting.

06

Turnkey Service

Or skip the capex: send devices to Richardson and we run the burn-in and return the data.